Products

AC variable frequency power supply

ALC-25 series railway signal source

ALC-25 series railway signal source

Download

 

 



 

 

◆ Microprocessor logic control, DDS type sine wave generation, bipolar full-bridge SPWM inverter; pure output waveform。

◆ Wide AC input range, input voltage fluctuation range ±30%. Input and output are completely isolated。

◆ An LC peak voltage filter is added to the input, which can filter out the peak voltage below 600V of the grid。

◆ The two outputs are isolated from each other, and the inverter control is isolated, without the need for an isolation transformer at the output end。

◆Adopt active soft switch power factor correction to make the input power factor reach 0.99。

◆ LCD and LED dual display, clearly understand the various conditions and parameters of the power supply。

◆ This machine has a fault self-test function, which can automatically detect, process and alarm for faults。

◆ When the input is switched between two channels, the module can provide a continuous flow time of 150 milliseconds。

◆ The switching time of dual-system hot backup is less than 25 milliseconds。

◆ Modules can be used in hot backup in parallel, and switch automatically within 25 milliseconds after failure。

◆ Meet the electromagnetic compatibility TB/T3073-2003, CLASS A requirements。

◆ The design of the power supply screen complies with the railway standard TB/T1528.1-2002 "Railway Signal Power Supply Screen Part I General Provisions", TB/T1528.7-2002 "Railway Signal Power Supply Screen Part 7: 25Hz Signal Power Supply Screen"。

If the following requirements fail to meet your parameter requirements, you can call to customize!

 

 

 

 

model

ALC25-2000

ALC25-4000

capacity

2KW

4KW

enter

Input rated voltage

AC220V (rail, local sharing), 50Hz

Input voltage range

Input ±25% of rated voltage

Input frequency range

47~63 Hz

Input power factor

≥0.99

Output

The output voltage

 

track

AC220V ±6.6V

AC220V ±6.6V

Partial

AC110V±3.3V

AC110V±3.3V

Output current

 

track

5.5A

10.9A

Partial

7.3A

14.5A

Output Power

 

track

1200W@220V

2400W@220V

Partial

800W@110V

1600W@110V

Output frequency

25HZ±0.4%

Phase

The output voltage phases of the two main and standby modules are synchronized, and the local power phase is 90° ahead of the track power

Phase angle accuracy

≤±3 degrees

Total harmonic content

≤3%

Dynamicvoltageresponse

Overshoot 10% (when load changes from 0-50-100%), stabilization time 0.2 seconds

Deviceoverloadcapacity

110% for 10 minutes; 150% for 10 seconds

DC component

Output DC component 1V

Displayfunction

Power, fault, power supply LED indication

Overallefficiency(fullload)

η≥88%

protect

Output short circuit protection

After the power output is short-circuited, stop the output

Output overcurrent protection

When the host is running, the output load is 110%, the module is protected, the fault light is on, and it switches to the standby machine to work

Input undervoltage protection

The input voltage is reduced to 155±5VAC, the fault light is on, and it switches to standby operation

Input overvoltage protection

The input voltage is boosted to 285±5VAC, the fault light is on, and it switches to standby operation

Output undervoltage protection

200VAC±5V, protect and switch to standby machine

Whole machine overheating protection

Air cooling, load control fan speed regulation, protection when the internal temperature is greater than 85

Conversion method

Active/standby conversion. When any module fails, it should be able to automatically switch to the standby module, and unplug any module.

Two-machine switching time

When one module is used, the other module should be able to work normally.

Electromagnetic Compatibility

Less than 25 milliseconds

Machine noise

The TB/T 3073-2003 standard meets the requirements of the TB/T 3073 2003 standard in the railway industry.

other

60dB

Dielectric strength

Insulationresistance

≥100MΩ

Dielectric strength

AC2000V 10mA 1min

MTBF

≥100000H

Dimensions

1/2模块(310×343×445mm)

working environment

storage temperature

-30℃~+55℃

Operatingtemperature

-10℃~+50℃

Relative humidity

≤90%

Atmosphericpressure

106-74.8Kpa (under 2500 meters above sea level)

Interface definition

Meet the standards of the Ministry of Railways