◆ Microprocessor logic control, DDS type sine wave generation, bipolar full-bridge SPWM inverter; pure output waveform。
◆ Wide AC input range, input voltage fluctuation range ±30%. Input and output are completely isolated。
◆ An LC peak voltage filter is added to the input, which can filter out the peak voltage below 600V of the grid。
◆ The two outputs are isolated from each other, and the inverter control is isolated, without the need for an isolation transformer at the output end。
◆Adopt active soft switch power factor correction to make the input power factor reach 0.99。
◆ LCD and LED dual display, clearly understand the various conditions and parameters of the power supply。
◆ This machine has a fault self-test function, which can automatically detect, process and alarm for faults。
◆ When the input is switched between two channels, the module can provide a continuous flow time of 150 milliseconds。
◆ The switching time of dual-system hot backup is less than 25 milliseconds。
◆ Modules can be used in hot backup in parallel, and switch automatically within 25 milliseconds after failure。
◆ Meet the electromagnetic compatibility TB/T3073-2003, CLASS A requirements。
◆ The design of the power supply screen complies with the railway standard TB/T1528.1-2002 "Railway Signal Power Supply Screen Part I General Provisions", TB/T1528.7-2002 "Railway Signal Power Supply Screen Part 7: 25Hz Signal Power Supply Screen"。
If the following requirements fail to meet your parameter requirements, you can call to customize!
model
|
ALC25-2000
|
ALC25-4000
|
capacity
|
2KW
|
4KW
|
enter
|
Input rated voltage
|
AC220V (rail, local sharing), 50Hz
|
Input voltage range
|
Input ±25% of rated voltage
|
Input frequency range
|
47~63 Hz
|
Input power factor
|
≥0.99
|
Output
|
The output voltage
|
track
|
AC220V ±6.6V
|
AC220V ±6.6V
|
Partial
|
AC110V±3.3V
|
AC110V±3.3V
|
Output current
|
track
|
5.5A
|
10.9A
|
Partial
|
7.3A
|
14.5A
|
Output Power
|
track
|
1200W@220V
|
2400W@220V
|
Partial
|
800W@110V
|
1600W@110V
|
Output frequency
|
25HZ±0.4%
|
Phase
|
The output voltage phases of the two main and standby modules are synchronized, and the local power phase is 90° ahead of the track power
|
Phase angle accuracy
|
≤±3 degrees
|
Total harmonic content
|
≤3%
|
Dynamicvoltageresponse
|
Overshoot ≤10% (when load changes from 0-50-100%), stabilization time ≤0.2 seconds
|
Deviceoverloadcapacity
|
110% for 10 minutes; 150% for 10 seconds
|
DC component
|
Output DC component ≤ 1V
|
Displayfunction
|
Power, fault, power supply LED indication
|
Overallefficiency(fullload)
|
η≥88%
|
protect
|
Output short circuit protection
|
After the power output is short-circuited, stop the output
|
Output overcurrent protection
|
When the host is running, the output load is 110%, the module is protected, the fault light is on, and it switches to the standby machine to work
|
Input undervoltage protection
|
The input voltage is reduced to 155±5VAC, the fault light is on, and it switches to standby operation
|
Input overvoltage protection
|
The input voltage is boosted to 285±5VAC, the fault light is on, and it switches to standby operation
|
Output undervoltage protection
|
200VAC±5V, protect and switch to standby machine
|
Whole machine overheating protection
|
Air cooling, load control fan speed regulation, protection when the internal temperature is greater than 85℃
|
Conversion method
|
Active/standby conversion. When any module fails, it should be able to automatically switch to the standby module, and unplug any module.
|
Two-machine switching time
|
When one module is used, the other module should be able to work normally.
|
Electromagnetic Compatibility
|
Less than 25 milliseconds
|
Machine noise
|
The TB/T 3073-2003 standard meets the requirements of the TB/T 3073 2003 standard in the railway industry.
|
other
|
≤60dB
|
Dielectric strength
|
Insulationresistance
|
≥100MΩ
|
Dielectric strength
|
AC2000V 10mA 1min
|
MTBF
|
≥100000H
|
Dimensions
|
1/2模块(310×343×445mm)
|
working environment
|
storage temperature
|
-30℃~+55℃
|
Operatingtemperature
|
-10℃~+50℃
|
Relative humidity
|
≤90%
|
Atmosphericpressure
|
106-74.8Kpa (under 2500 meters above sea level)
|
Interface definition
|
Meet the standards of the Ministry of Railways
|