◆ Made of stainless steel alloy resistors。
◆ The discharge power can be set according to the power detection requirements, and can be put in a combination of buttons。
◆ Detect the working efficiency of various power generation equipment and discharge equipment, the maximum output power and load capacity of full load operation。
◆ Simulate various complex working environments, sudden increase and unload of power, and detect the actual loading capacity and efficiency of the discharge equipment。
◆ The use of precise and high-precision load materials can truly simulate the actual load's loading force and the ability to adapt to slight changes in the load。
◆ Emergency stop and temperature protection, overload, short circuit, over-temperature equipment automatically cut off。
◆ Upper limit and lower limit voltage setting, automatically drop to the range voltage point according to the energy (Limited program control machine)。
◆ Temperature protection setting, temperature 0~100° can be set, and real-time temperature condition can be detected at the same time。
◆ Programmable interface 0~30 groups of power and current can be set arbitrarily, the minimum execution time is 1ms and can be cycled 999999 times (limited to program-controlled machine)。
◆ The minimum resolution of the load is 1W, which can accurately simulate the power generation or on-off capability of the product。
◆ It is possible to upload the measurement data to the computer and realize the process record and storage function of the detection process data (only programmable controller)。
◆ There are two operation modes: panel operation or remote control (program-controlled machine only)。
◆ With over-temperature protection function, temperature setting and temperature monitoring。
◆ Different time constant loads can be customized。
◆ Used in generators, UPS, switches, fuses, electrical accessories, transformers, temperature rise tests, low-voltage electrical factory inspection, production debugging, simulation of harsh loads,Accurate testing sites for environment, scientific research and development, military industry, etc。
◆ Use button control or switch switch (touch screen control with RS232 communication interface)。
◆ Can measure voltage, current, power。
Charging pile / electricity/communication / telecom / netcom/mobile / unicom / tietong / civil aviation / inverter / DC generator set / auto 4S shop battery maintenance test maintenance and other industries.
DLB-LR DC group load (including program control)
|
product name
|
12V vehicle power supply test load
|
24V DC power supply test load
|
28V aviation power test load
|
48V DC screen test load
|
220V DC switching power supply discharge load
|
500V charger test load
|
Special test load for 600V ground power locomotive
|
Model number
|
DLB-LR series
|
Main technical indicators of load box
|
The specific voltage value and power value can be customized according to user needs
|
Rated voltage
|
DC 12V
|
DC 24V
|
DC 28V
|
DC 48V
|
DC 220V
|
DC 380V
|
DC 600V
|
rated power
|
5KW
|
12KW
|
14KW
|
24KW
|
22KW
|
190KW
|
300KW
|
Load nature
|
Purely resistive
|
Purely resistive
|
Purely resistive
|
Purely resistive
|
Purely resistive
|
Purely resistive
|
Purely resistive
|
control method
|
DC circuit breaker
|
DC circuit breaker
|
DC circuit breaker
|
DC circuit breaker
|
DC circuit breaker
|
DC contactor
|
DC contactor
|
ElectriccurrentSegmented
|
5A-180A
|
1A-500A
|
1A-500A
|
1A-500A
|
1A-100A
|
1A-400A
|
1A-500A
|
Voltage accuracy
|
0.50%
|
0.50%
|
0.50%
|
0.50%
|
0.50%
|
0.50%
|
0.50%
|
Voltage resolution
|
0.1V
|
0.1V
|
0.1V
|
0.1V
|
0.1V
|
0.1V
|
0.1V
|
Adjustmentaccuracy
|
±5%
|
±5%
|
±5%
|
±5%
|
±5%
|
±5%
|
±5%
|
the meter shows
|
无
|
LED digital ammeter, voltmeter (other meters are optional)
|
LED digital ammeter, voltmeter (other meters are optional)
|
LED digital ammeter, voltmeter (other meters are optional)
|
LED digital ammeter, voltmeter (other meters are optional)
|
LED digital ammeter, voltmeter (other meters are optional)
|
LED digital ammeter, voltmeter (other meters are optional)
|
Load protection
|
Overcurrent protection, high temperature alarm, fan failure alarm (optional)
|
Overcurrent protection, high temperature alarm, fan failure alarm (optional)
|
Overcurrent protection, high temperature alarm, fan failure alarm (optional)
|
Overcurrent protection, overvoltage protection, high temperature alarm, fan failure alarm (optional)
|
Overcurrent protection, overvoltage protection, high temperature alarm, fan failure alarm (optional)
|
Overcurrent protection, overvoltage protection, high temperature alarm, fan failure alarm (optional)
|
Overcurrent protection, overvoltage protection, high temperature alarm, fan failure alarm (optional)
|
Cooling method
|
Forced air cooling
|
Forced air cooling
|
Forced air cooling
|
Forced air cooling
|
Forced air cooling
|
Forced air cooling
|
Forced air cooling
|
Size W*L*H
|
480*650*600mm
|
480*650*600mm
|
480*800*820mm
|
600*900*1000mm
|
600*900*1000mm
|
1200*950*1600mm
|
1100*1450*1700mm
|
Optionalfunction
|
/
|
/
|
Computer remote monitoring
|
Computer remote monitoring
|
Computer remote monitoring
|
Computer remote monitoring
|
Computer remote monitoring
|
|
|
|
|
|
Touch screen control
|
Touch screen control
|
Touch screen control
|
Touch screen control
|
Touch screen control
|
|
|
|
|
|
Report printing
|
Report printing
|
Report printing
|
Report printing
|
Report printing
|
接下表:
product name
|
32V battery discharge test load
|
48V battery discharge test load
|
750V charging pile test load
|
800V charging pile test load
|
1000V charging pile test load
|
750V charging pile test load
|
750V charging pile test load
|
Model number
|
DLB-LR series
|
Main technical indicators of load box
|
The specific voltage value and power value can be customized according to user needs
|
Model number
|
DLB-LR5/32
|
DLB-LR120/48
|
DLB-LR60/075
|
DLB-LR60/08
|
DLB-LR120/010
|
DLB-LR200/07-5
|
DLB-LR300/07-5
|
Rated voltage
|
DC 32V
|
DC48V
|
DC 750V
|
DC 800V
|
DC 1000V
|
DC 750V
|
DC750V
|
rated power
|
5KW
|
120KW
|
60KW
|
60KW
|
120KW
|
200KW
|
300KW
|
Load nature
|
Purely resistive
|
Purely resistive
|
Purely resistive
|
Purely resistive
|
Purely resistive
|
Purely resistive
|
Purely resistive
|
control method
|
DC circuit breaker
|
DC circuit breaker
|
DC circuit breaker
|
DC circuit breaker
|
DC circuit breaker
|
DC contactor
|
DC contactor
|
ElectriccurrentSegmented
|
1A-160A
|
1A-250A
|
1A-80A
|
1A-75A
|
1A-120A
|
1A-267A
|
1A-400A
|
Voltage accuracy
|
0.50%
|
0.50%
|
0.50%
|
0.50%
|
0.50%
|
0.50%
|
0.50%
|
Voltage resolution
|
0.1V
|
0.1V
|
0.1V
|
0.1V
|
0.1V
|
0.1V
|
0.1V
|
Adjustment accuracy
|
±5%
|
±5%
|
±5%
|
±5%
|
±5%
|
±5%
|
±5%
|
the meter shows
|
LED digital ammeter, voltmeter (other meters are optional)
|
LED digital ammeter, voltmeter (other meters are optional)
|
LED digital ammeter, voltmeter (other meters are optional)
|
LED digital ammeter, voltmeter (other meters are optional)
|
LED digital ammeter, voltmeter (other meters are optional)
|
LED digital ammeter, voltmeter (other meters are optional)
|
LED digital ammeter, voltmeter (other meters are optional)
|
Load protection
|
Overcurrent protection, high temperature alarm, fan failure alarm (optional)
|
Overcurrent protection, high temperature alarm, fan failure alarm (optional)
|
Overcurrent protection, high temperature alarm, fan failure alarm (optional)
|
Overcurrent protection, overvoltage protection, high temperature alarm, fan failure alarm (optional)
|
Overcurrent protection, overvoltage protection, high temperature alarm, fan failure alarm (optional)
|
Overcurrent protection, overvoltage protection, high temperature alarm, fan failure alarm (optional)
|
Overcurrent protection, overvoltage protection, high temperature alarm, fan failure alarm (optional)
|
Heatdissipationmethod
|
Forced air cooling
|
Forced air cooling
|
Forced air cooling
|
Forced air cooling
|
Forced air cooling
|
Forced air cooling
|
Forced air cooling
|
Size W*L*H
|
480*650*600mm
|
940*950*1500mm
|
650*900*1200mm
|
650*900*1200mm
|
940*950*1500mm
|
1200*950*1600mm
|
1100*1450*1700mm
|
Optionalfunction
|
/
|
/
|
Computer remote monitoring
|
Computer remote monitoring
|
Computer remote monitoring
|
Computer remote monitoring
|
Computer remote monitoring
|
|
|
|
|
|
Touch screen control
|
Touch screen control
|
Touch screen control
|
Touch screen control
|
Touch screen control
|
|
|
|
|
|
Report printing
|
Report printing
|
Report printing
|
Report printing
|
Report printing
|
◆ The company's product specifications are continuously developed and improved, and are subject to change without notice
◆ You can contact the company’s technical staff for inquiries and technical support
◆ For special specifications, please call the business department of the company, and the company accepts special customization for user needs