Products

AC variable frequency power supply

ALC1000S series three-phase AC power supply

ALC1000S series three-phase AC power supply

Download

 

 


 

 

 

 

■ Pure power output quality:

110V/220V dual power conversion, providing pure and reliable sine wave (Sine Wave) output. Not only the best source for R&D and laboratories, but also the standard power supply for EMI/EMC and other safety testing.

■ Excellent stability:

The output load voltage is ≤±1%, and the output frequency is ≤±0.01%. The output frequency is generated by a quartz crystal oscillator, which has a very stable and accurate frequency output.

■ High efficiency IGBT module:

Save electricity, energy, and money. The use of insulated gate transistor (IGBT) modules can promote high-power output, improve quality stability, and reduce power loss and interference;

■ Directly select the output frequency file:

47~63Hz, 50Hz, 60Hz (2F, 4F, 400Hz optional) can be used for transformer, coil, etc. for interlayer withstand voltage test.

■ Fast transient response speed:

For 100% unloading/loading, the output load regulation rate (response time) can be immediately stabilized at ±1% (linear load).

■ Strong overload capacity:

100% full load is allowed for long-term use; when the instantaneous load capacity exceeds 3 times the rated current, the power supply can withstand it and will not cause a voltage drop.

■ Multiple safety protection functions:

It has over-voltage, over-current, over-temperature, short-circuit protection and alarm devices. In case of abnormal conditions, the electronic circuit of the machine will automatically sense and immediately cut off the output.

An alarm will be issued at the time to notify the user to deal with an emergency situation.

■ Suitable for various loads:

It can be used for resistive, capacitive, inductive or non-linear loads;

■ High measurement accuracy, suitable for testing of current sine half-wave and similar waveforms with DC components.

■ Customizable analog control for better PC control or program control

 

 

 

 

◆ Export electrical/electronic/motor manufacturers/replaceable power supply/transformer testing

◆ Compressor/motor related product test/Monitor test

◆ Test of air-conditioning equipment / Test of various electrical products

◆ Fluorescent lamp rectifier test / production plant (quality assurance / control / life test) and other units

◆ Output 400Hz dedicated power supply: military systems, aviation systems, navigation systems, switching power supplies for supercomputers, etc.

◆ Export electrical/electronic/motor manufacturers

 


 


ALC1000S standard three-phase AC power supply

model

1006S

1009S

1012S

1015S

1020S

1030S

1060S

1100S

1150S

1300S

1450S

capacity

6KVA

9KVA

12KVA

15KVA

20KVA

30KVA

60KVA

100KVA

150KVA

300KVA

450KVA

Production method

SPWM (Sine Pulse Width Modulation)

 

 

enter

Phase

1φ2W

3φ4W

Phase voltage

220V±10%

380V±10%

frequency

47Hz ~ 63Hz

 

 

 

 

Output

Phase

1φ2W

Voltage

Low gear 0-150VAC/High gear 0-300VAC Automatic transmission AUTO

frequency

45~200Hz (40 ~500Hz, 10 ~1000Hz needs to be customized) 0.1Step

 

Maximumphase Current

L=120V

16.8A

25A

33A

42A

56A

84A

168A

278A

420A

840A

1250A

H=240V

8.4A

12.5A

17A

21A

28A

42A

84A

139A

210A

420A

625A

Display LED (Phase A)

Voltage, current, frequency, power, power factor PF, peak current AP

Power supply voltage regulation rate

0.1%

Load regulation rate

1 %

Waveform distortion

2% (pure resistive load)

Frequency stability

0.01%

Voltage resolution

0.1V

Frequency resolution

0 . 1 Hz

Current resolution

0.01A

0.1A

1A

        


   Measurementaccuracy

Voltage

0.5%FS+5dgt

Current

0.5%FS+5dgt

power

0.5%FS+5dgt

frequency

0.01%FS+5dgt

Settingaccuracy

Voltage

1%FS

frequency

0.1%FS

Number of storage groups

M1 (V_F_A), M2 (V_F_A), …M9 (V_F_A)

Communication Interface

RS232C [IEEE488.2 (GPIB) optional]

Current limit setting

O-Max Current

protect

Over current, over temperature, overload, short circuit

weight

75

90

120

150

200

300

500

900

1200

2000

3000

volume

430×700×700

610×930×1050

700×1200×1400

900×1580×1610

100×1580×1800

Operating environment

0 ~40℃                  20~80%RH

  


▲ For special specifications, please call the business department of the company, and the company accepts special customization according to user needs