AHY-12 standard series AC constant current source is a steady current source with wide frequency spectrum, high precision, low harmonics and distortion. The constant current source is an AC power source that can keep the output current constant when the external grid power source fluctuates or the power consumption conforms to the impedance characteristics. The power supply is mainly used in products and places where specific current heating effects are applied and tested. Such as circuit breakers, fuses, thermal relays, magnetic starters, coils, etc. require experiments。
◆ The AC constant current source is specially designed and manufactured for users of low-voltage electrical appliances. Its output current is constant and the output waveform is pure sine wave. It can be used as an overcurrent test instrument.
◆ This AC constant current source can carry resistive, inductive, and capacitive loads to meet the requirements of low-voltage electrical appliances for test power supplies.
◆ Outstanding advantages, high accuracy of steady flow, can be 1%, 0.8%, 0.5%, 0.3% level according to the user's use environment. Ensure that the output current is constant. The large current generator scheme used before is due to
With temperature changes, the copper resistance of wires, joints and coils has been changing.
◆ The operator must frequently adjust the voltage regulator to achieve a constant current, which is time-consuming and energy-consuming, and the accuracy cannot be compared with this power supply. In the production of low-voltage electrical appliances, the current must be checked and aged.
At present, the use of this power supply is the best choice at present, such as the setting of the operating current of the thermal relay and the measurement of the thermal trip current of the air switch.
◆ It can carry out automated tests of different current levels (items: voltage, current, frequency, rise and fall time, and cycle test operations).
◆ Frequency adjustable range: 40-500HZ (optional), fixed output: 50HZ, 60HZ (fixed output frequency in more ranges can be designed according to user needs).
◆ Analog quantity (signal) control can be set for users.
AC air switch / AC contactor / mechanical switch / electronic switch / AC transformer / thermal relay / molded case circuit breaker / small short-circuit device and need to set rated current
Action current / short-circuit protection current, etc. / automatic testing and verification platform / current requirement test place
AHY-12 ordinary series AC constant current source
|
Model number
|
AHY-12-10-50
|
AHY-12-10-100
|
AHY-12-10-200
|
AHY-12-10-300
|
AHY-1 2-10-500
|
AHY-12-10-1000
|
AHY-12-10-1500
|
AHY-12-10-2000
|
AHY-12-10-3000
|
AHY-12-10-5000
|
AHY-12-10-4500
|
AHY-12-10-6000
|
AHY-12-10-7000
|
AHY-12-10-8000
|
AHY-12-10-1 M
|
Production method
|
SPWM
|
Input
|
Number of phases
|
1φ2W(≤10KW) 3φ4W(≥10KW)
|
Voltage
|
220V+10%(≤10KW) 380V+10%(≥10KW)
|
frequency
|
47 Hz - 63 Hz
|
Output
|
Number of phases
|
1φ2W(3φ4W optional)
|
Voltage
|
0-3000V (optional)
|
frequency
|
45Hz-63Hz continuous adjustment fixed 50Hz/60Hz, (40-500 optional)
|
wiring
|
Small current terminal high current output copper bar
|
protect
|
The electronic circuit quickly recognizes the over current, over voltage, and over temperature and automatically falls off, and the non-test state VA=0
|
LED display
|
Voltage, current, frequency, power, power factor PF
|
Power regulation rate
|
0.1%
|
Load regulation rate
|
0.5FS %
|
Waveform distortion rate
|
2% (pure resistive load)
|
Frequency stability
|
0.01%
|
Voltage resolution
|
0.1 V
|
Current resolution
|
0.001 A/0.01 A/0.1 A/1 A
|
Frequency resolution
|
0.1Hz
|
measurement accuracy
|
Voltage
|
0.5 % FS±5dgt
|
Electric current
|
0.5 % FS±5 dgt
|
power
|
0.5 % FS±5 dgt
|
frequency
|
0.01 % FS±5 dgt
|
Setting accuracy
|
Voltage
|
1 % FS
|
frequency
|
0.1 % FS
|
protect
|
Over current, over temperature, overload
|
Operating environment
|
Temperature: 0-45°C Relative humidity: 0-90% (non-condensing state) Altitude 1500m
|
Insulation reactance
|
500Vdc 20MQ or more
|
Withstand voltage insulation
|
1800Vac/5mA/1 minute
|
cooling method
|
Forced air cooling
|
Communication Interface
|
RS232C/485 provides corresponding communication protocol
|
Custom function
|
Voltage / customizable appearance
|
efficiency
|
≥98
|
noise
|
≤60DB (1m)
|
Protection level
|
IPX20
|
Transformer accuracy
|
0.2S
|
volume
|
Inquiry factory
|
weight
|
15kg~900kg
|
Remark
|
The above models are our regular models, and the remaining voltage and current levels can be determined by referring to the actual needs of users.
|
Note: This product is constantly updated, technical parameters are subject to change without notice. Voltage and current levels can be customized according to user needs